Technical Feature & Parameter
Instruction
Rated voltage
| DC6V |
Coil resistance
| 12±0.5Ω(20℃) |
Min Current
| 333mA |
Switch mode
| DC pulse(latching type)
|
Pulse width
| ≥30ms |
Operating pressure
| 0.05Mpa-0.8Mpa |
Media temperature
| 1℃-75℃ |
Responding time
| Open≤0.15s close≤0.5s
|
Performance test
Strength test
| Withstand voltage pressure
| 2.5Mpa/1min |
No-load test
| Voltage3.6V
| Permissible limiting voltage
| VoltageV*1.15
|
High water pressure start and close
| At water pressure 0.8MPa,voltage DC4V,pulse width 30ms,the solenoid valve can be started and closed normally
|
low water pressure start and close
| At water pressure 0.02MPa,voltage DC4V,pulse width30ms,the solenoid valve can be started and closed normally
|
Leakage upon high water pressure
| 1.2MPa without leakage
|
Leakage upon low water pressure
| 0.05Mpa without leakage
|
Electric strength
| Among conductive part, mounting hole and nonconductive metal, it can withstand 500V/50Hz,leakage current 0.75mA for 1 min without the breakdown
|
Insulation resistance
| The resistance between the charged part and nonconductive metal part tested by megohm meter of 500V ≥20MΩ
|
Sealing test
| Static pressure
| Air
| High pressure
| 1Mpa |
Low pressure
| 0.05Mpa |
Cold water
| High pressure
| 1.2Mpa |
Low pressure
| 0.05Mpa |
Hot water
| High pressure
| 0.8Mpa |
Low pressure
| 0.05Mpa |
Service life
| ≥1200000 cycles(CJ/T 194-2004)
|
Requirements of working environment
Temp of working environment
| 1℃-60℃ | Permissible limiting pressure(water)
| ≤1.2Mpa |
Humidity of working environment
| 35%-90% RH(No condensation state)
| Mounting direction
| It is mounted in vertical. The inclination do not exceed 15 degrees
|
Storage temp
| -5-80℃( no freezing state)
|
|
Storage humidity
| 25%-95% RH(No condensation state)
|
|
Relation between pressure and flow rate
Pressure(Mpa)
| 0.02 | 0.05 | 0.1 | 0.2 | 0.3 | 0.4 | 0.5 | 0.6 | 0.7 | 0.8 |
Average flow rate(L/min)
| 1.5 | 5 | 15 | 24 | 29 | 34 | 38 | 41 | 43 | 45 |